Prospectively assessed menstrual cycle characteristics in female wafer- fabrication and nonfabrication semiconductor employees

Gold EB, Eskenazi B, Hammond SK, Lasley BL, Samuels SJ, O'Neill Rasor M, Hines CJ, Overstreet JW, Schenker MB

Am J Ind Med. 1995. 28(6):799-815.

Women aged 18-44 years in silicon-wafer fabrication-room (fab) jobs and frequency-matched women in nonfab jobs were screened for a prospective study of reproductive health (n = 2,639). Among the 739 (28%) eligible women, 481 (65%) completed a baseline interview; 402 completed at least one menstrual cycle of follow-up with daily diaries and urinary assays to exclude conceptive cycles. Adjusted mean cycle lengths (MCL) did not differ between fab and nonfab women (p = 0.97). Women working in thin film and ion implantation (TFII) had the highest adjusted MCL (34.8 +/- 1.7 days) compared with nonfab workers (32.5 +/- 1.4 days, p = 0.07). Among women working exclusively in one group, TFII women had significantly higher MCL (36.1 +/- 2.04 days) than nonfab women (32.0 +/- 1.38 days, p = 0.017). TFII women were also more likely to have all cycles > 35 days (adjusted relative risk [RR] = 2.45; 95% CI = 0.85- 6.06). Variability was assessed by logarithmic transformation of the mean standard deviation (MLSD) in cycle length per woman and adjusted for age and ethnicity (4.5 days for fab vs. 4.0 days for nonfab, p = 0.16). Women working exclusively in TFII or photolithography (PHOTO) had significantly higher adjusted MLSD in cycle length (6.68 +/- 1.28 and 5.72 +/- 1.24 days, respectively) than women in nonfab (4.1 +/- 1.16 days, p = 0.013 and 0.019, respectively). Fab and nonfab women did not differ significantly in mean days of bleeding or risk of having cycles > 35 or 24 days. However, elevated risks of having cycles 24 days were seen in supervisor engineers (adjusted RR = 2.46, 95% CI = 1.19-3.63) and PHOTO women (adjusted RR = 1.83, 95% CI = 0.94-2.88).

Keywords: Adolescence, Adult, Female, Human, Menstrual Cycle/*physiology, *Occupational Health, Prospective Studies, *Semiconductors, Silicones, Support, Non-U.S. Gov't, Support, U.S. Gov't, P.H.S.



Close Window

UC Davis Health System is pleased to provide this information for general reference purposes only. It should not be considered as a substitute for professional medical advice. You are urged to consult with your health care provider for diagnosis of and treatment for any health-related condition. The information provided herein may not and should not be used for diagnosis and treatment.

Reproduction of material on this web site is hereby granted solely for personal use. No other use of this material is authorized without prior written approval of UC Regents.